Preface
To ensure occupational safety, delivery reliability and the correct quality, this note has been compiled and must be regarded as a necessary measure for the above to be implemented. It is expected that the following Executive Orders from the Danish Working Environment Authority are complied with:
This note will refer to the sections of the Executive Order that are of particular interest for:
1. Traffic and access routes
Executive Order of the Danish Working Environment Authority no. 1516 §46:
Subsection 1. The construction site must be arranged with a sufficient number of access and transport routes, including stairs, loading platforms and ramps. They must be located, made usable and dimensioned so that they can be used without danger to safety and health and so that persons working near these access and transport routes are not exposed to danger to safety and health. Access, transport and traffic areas must, to the necessary extent, be arranged so that suitable technical aids can be used.
Subsection 2. Traffic routes and areas must be kept level and free of materials or objects that may pose a hazard to traffic. Shafts, holes, etc. must be covered or cordoned off.
Zystm requirement:
A truck is max. 2.6 metres wide and normally 16.5 metres long; any straight access road must therefore be at least 3.0 metres wide.
If the access road is not level, a ramp must be constructed with a suitably gentle incline (max 1:10).
The access conditions outside the building must allow the use of a pallet truck, as well as inside with a floor-covered protective layer. It is expected that materials, tools, cables, etc. are not placed in a way that poses a hazard to traffic on the access routes, and that door openings are min. 85 cm.
In connection with multi-storey construction, where Zystm is to deliver and install products on floors above ground level, there must be access to an external construction hoist min. 3 metres deep, or an internal approved lift near the access road and unloading area. The unloading area must be constructed with a solid base, such as road plates, level concrete or equivalent.
2. Installation conditions on the construction site
Executive Order of the Danish Working Environment Authority no. 117 §11:
Subsection 3. That necessary technical installations are established and brought to the points of use in due time and, to the necessary extent, are inspected and maintained.
Zystm requirement:
Where possible, there must be artificial lighting at the workplace and work areas, rooms and access routes when daylight is not sufficient. Reservations are made for hidden installations (electricity, water, sewer, gas, etc.)—their location must be stated before installation. Installations requiring Zystm’s attention, e.g. holes and penetrations in the floor for drainage, routing of services to be connected to fittings, require special marking so that Zystm is aware of the location.
Wall: For wall mounting, it must be assumed that the wall is of a nature that allows fastening with the necessary screws/bolts and plugs, and that the wall is level; any levelling/repair of level differences is extra.
Floor: A level difference of max. 2.5 mm per running metre of floor can be accepted. Any additional shimming is not included in the price. It is assumed that the floor is of a nature that makes it possible to anchor the fittings with standard expansion bolt M10x90 mm. It is expected that the relevant rooms have a floor-covered protective layer, are emptied, builders-cleaned and ready for installation.
3. Material storage areas
Executive Order of the Danish Working Environment Authority no. 117 §11:
Subsection 6. That materials can be placed in a suitable location and on a stable surface.
Zystm requirement:
It is requested that the materials are placed directly at the installation location for faster completion of installation. If this request cannot be met, the distance to the material storage area must be max. 50 metres from the installation location.
4. Order and tidiness
Executive Order of the Danish Working Environment Authority no. 1516 §59:
Subsection 1. The construction site must be kept orderly and tidy so that conditions are at all times fully safe and healthy. In particular, it must be ensured that waste, etc. is placed in suitable locations and disposed of in a responsible manner.
Zystm requirement:
That an available waste container is placed max. 100 metres from the installation location and is continuously emptied as needed. By special agreement, Zystm can bring a waste container, which must be agreed in writing.
5. Coordination of work areas where several companies are to carry out work simultaneously
Executive Order of the Danish Working Environment Authority no. 117 §9:
Subsection 1. Where the client has several designers carry out a construction project, the client must help ensure that any interfaces between the individual project managers’ different project parts are defined clearly and distinctly.
Zystm requirement:
That the client has coordinated the interaction between the contractors involved at the relevant installation location, for the performance of work before, between and after Zystm’s
installation work. This coordination must be set out in a detailed construction schedule.
If the above points are not met, we (Zystm A/S) reserve the right to pass on incurred costs.